论文标题

PIP2IT的机器保护系统的经验

Experience With Machine Protection Systems At PIP2IT

论文作者

II Collaboration, Warner, A., Austin, M., Carmichael, L., Carneiro, J. -P., Hanna, B., Harms, E., Neswold, R., Prost, L., Rivera, R., Shemyakin, A., Ibrahim, M., Wu, J.

论文摘要

PIP-II喷油器测试1 PIP2IT设施加速器在2014年以多个阶段组装,$ 2021,以测试Fermilab正在建造的未来Pipii Linac的概念和组件。在最终配置中,Pip2IT加速了0.55 ms x 20 Hz x 2 ma h $-$ beam to 16 meV。为了保护光束线的元素,实施了机器保护系统议员。当检测到过多的光束损耗时,梁被中断的速度比10 $ $ s的速度快。本文描述了MPS架构,损耗检测的方法,光束中断的过程以及PIP2IT的操作经验。

The PIP-II Injector Test 1 PIP2IT facility accelerator was assembled in multiple stages in 2014 $-$ 2021 to test concepts and components of the future PIPII linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H$-$ beam to 16 MeV. To protect elements of the beam line, a Machine Protection System MPS was implemented and commissioned. The beam was interrupted faster than 10$μ$s when excessive beam loss was detected. The paper describes the MPS architecture, methods of the loss detection, procedure of the beam interruption, and operational experience at PIP2IT.